            1. Reagent Center

              Aquatic Pathogen Series

              • Aquatic Pathogen Series Reagents MORE
                Product Details:

                In this series of products, primers and TaqMan probes are designed with virus specific gene fragments to realize rapid qualitative detection of viral nucleic acids in aquatic and economic animals such as shrimp and fish. It can be used for virus tracking detection in the breeding process, and also for environmental monitoring, so as to avoid the spread of virus and reduce economic losses. The series also has multi-channel reagents that simultaneously detect two diseases in the same tube.

                 

                 

                Main component

                Storage temperature

                Amplification reagents

                PCR reaction reagents

                -15~-25℃

                Primers probe

                Control

                Negative control

                Positive control

                 

                Product list

                Cat#

                Product Name

                Package

                Note

                BSN01S1

                White Spot Syndrome Virus Real Time PCR Detection Kit

                16T

                -20℃Storage

                BSN01M1

                32T

                BSN02S1

                Infectious hypodermal and haematopoietic necrosis virus Real Time PCR Detection Kit

                16T

                BSN02M1

                32T

                BSN03S1

                Shrimp Hemocyte Iridescent Virus Real Time PCR Detection Kit

                16T

                BSN03M1

                32T

                BSN04S1

                Vibrio Harveyi Real Time PCR Detection Kit

                16T

                BSN04M1

                32T

                BSN05S1

                EMS & EHP Dual Chanel Real Time PCR Detection kit

                16T

                BSN05M1

                32T

                BSN06S1

                Bacteria & Vibrio Dual Chanel Real Time PCR Detection Kit

                16T

                BSN06M1

                32T

                BSN07S1

                Taura Syndrome Virus Real Time PCR Detection Kit

                16T

                BSN07M1

                32T

                BSN08S1

                Yellow head virus Real Time PCR Detection Kit

                16T

                BSN08M1

                32T

                BSN09S1

                Enterocytozoon hepatopenaei Real Time PCR Detection Kit

                16T

                BSN09M1

                32T

                BSN10S1

                Acute Hepatopancreatic Necrosis Disease Real Time PCR Detection Kit

                16T

                BSN10M1

                32T

                 


                Product Features:

                1. It is suitable for the Bioer fluorescence quantitative PCR detection system and the same kind of real-time quantitative detection system

                2. High sensitivity: detection limit up to 100 copies/mL

                3. High specificity: The design of specific primers and probes can safely avoid cross reactions and the resulting false positives

                4. Easy to operate, short time consuming: the reagent adopts premixed form, less components, easy to operate, only need about 1 hour to complete whole experiment.

                5. DUTP-UNG system is used to effectively prevent contamination of PCR products

                Experimental data:

                Experiment 1

                White Spot Syndrome Virus Real Time PCR Detection Kit

                (1) Linear tests with concentrations of 102 to 107 copies/mL of DNA showed good results, R2=0.9985

                DNA(copies/mL)

                Ct

                Ct value

                106

                19.18

                19.2

                19.22

                105

                22.64

                22.63

                22.62

                104

                26.31

                26.37

                26.43

                103

                29.82

                29.83

                29.84

                102

                34.1

                34.11

                34.12

                 

                 

                 

                 

                (2) The test was repeated using lower concentrations of DNA

                 

                The results showed that the detection rate of low concentration DNA was 100%, and the reproducibility was good


                Experiment 2

                 Dual nucleic acid detection reagent linear test of acute hepatopancreas necrosis (EMS) and hepatoenterocytic worm (EHP) (DNA concentration 102 ~ 107copies/mL)

                DNA(copies/mL)

                EHP(FAM)

                EMS(HEX)

                106

                16.93

                16.42

                105

                20.3

                19.95

                104

                24.12

                23.41

                103

                27.73

                27.22

                102

                31.62

                31.48

                 




































                Manual download
              Privacy clause

              Respect the user's privacy is a basic policy of Hangzhou Bioer user service. Hangzhou Boier will not disclosure user information to third parties or disclose their registration and preservation of non disclosure in Hangzhou Bioer platform, except in the following situations: (1)User's improper behavior caused leakage of privacy information ; (2)Caused by network, hacker attack, computer virus, government regulation, the reasons of the leakage, lost, stolen or tampered with other relevant legal requirements; (3)Law-enforcement agency asked Hangzhou Bioer to provide privacy information of the user; (4)Emergency situation when public life and property security is under threate.

              Exemption clause

              Hangzhou Bioer technology does not guarantee the accuracy, integrity and reliability of any content on this website and any content that may use these results. Hangzhou Bioer technology and related people can not guarantee that you can enter, browse and use this website at any time; Hangzhou Bioer technology on this website and its contents can not use and do not take any responsibility. The site links to other websites that Hangzhou itself is not recognized or undertake other Bioer technology content or the use of responsibility. Hangzhou Bioer technology and related people to enter, browse and use of the site, from the website to download any content or by any link to this site to other sites caused by viruses or other destructive programs on your computer system and any other software and hardware, IT system or property damage or loss does not bear any responsibility. Hangzhou Bioer technology and the relevant people do not bear any responsibility caused by the third party using illegal means to obtain the password, data and content into the site of any direct and indirect damage or loss . The final interpretation belong to Hangzhou Bioer Technology Co. Ltd.

              Hangzhou Bioer reserves the right to correct, modify and update this statement at any time.

              Copyright

              This website from Hangzhou Bioer Technology Co. Ltd. (hereinafter referred to as "Hangzhou Bioer") the creation of any content of this website (including but not limited to text, data, graphics, images, voice or video) are copyright or related rights belong to Hangzhou Bioer. Hangzhou Bioer or related rights without prior written permission, you shall not in any way without permission to copy, reconstruction, spread, publishing, reprint, repost or display the contents of this website. Any unauthorized use of this site may violate the "Copyright Law of People's Republic of China " and other relevant laws and regulations and international conventions, Hangzhou Bioer fully pursue appropriate legal responsibility right.

              Contact Us

              Address: 1192 Bin An Rd, Hi-tech (Binjiang)District,Hangzhou,310053,P. R. China

              Tel:0571-87774567

              国产欧美在线一区二区三区
            2. <optgroup id="eakpv"><em id="eakpv"><pre id="eakpv"></pre></em></optgroup>
              <span id="eakpv"><sup id="eakpv"></sup></span>
                <ol id="eakpv"><output id="eakpv"></output></ol>

                1. <span id="eakpv"></span>

                2. <optgroup id="eakpv"><em id="eakpv"><pre id="eakpv"></pre></em></optgroup>

                  1. <span id="eakpv"></span>
                  2. <span id="eakpv"></span><acronym id="eakpv"></acronym>

                  3. <span id="eakpv"><output id="eakpv"><b id="eakpv"></b></output></span>